Transio A52/53 is a smart RS-232 to RS-422/485
bi-directional converter that comes with all of the great
technical
specs that Moxa is well known for. This includes data direction
control
built into the hardware for both RS-422 and RS-485 interfaces, LED
indicators for power and signal states, and surge protection and
isolation protection. These last two features take care of some of the
major problems faced by serial communication connections in industrial
environments.
Serial Connection Problems in Industrial
Environments
Serial communication and reliability can be adversely
affected in a hazardous industrial environment. The wiring associated
with serial communication devices could be surrounded by power lines,
motors, or equipment that produces static electricity. If this is the
case, the serial devices could be damaged by sudden surge waves
produced by this type of equipment. In this situation, surge protection
that uses TVSS (Transient Voltage Surge Supression) is the solution.
When two serial devices are directly connected, but
separated by a long distance, the unbalanced ground voltage could cause
serious damage. Unbalanced ground voltage between two serial ports
forms a "ground loop," introducing a large current between the two
pieces of serial equipment. In fact, the current could be so lare as to
damage the equipment beyond repair. In this situation, the solution is
to use Isolation Protection to completely isolate both communication
ports.
What is Surge Protection?
Surges are high amplitude pulses of only several
millionths of a second in duration. They can be caused by heavy-duty
equipment, power lines, short circuits, or large motors. A surge
suppressor has the ability to effectively absorb the high energy
instantly, thus preventing the connected devices from damage.
What is Isolation Protection?
Electrical isolation is achieved by using a photo
coupler to transform an electric signal into light, and then
retransform the light back into an electric signal on the other side.
In this way, the two electric circuits are completely isolated from
each other.
.Features
 |
ADDC™ (Automatic Data Direction Control) RS-485 data
control |
|
 |
Auto baudrate sensing |
|
 |
RS-422 hardware flow control: CTS, RTS signals |
|
 |
LED indicators for power and signal states |
|
 |
RS-485 multidrop operation, up to 32 nodes |
|
|
 |
Surge protection, 25 KV ESD |
|
 |
2 KV isolation protection (A53) |
|
 |
Built-in 120 Ω termination resistors |
|
Specifications
Communications |
|
|
|
| Tx, Rx, DTR, DSR, RTS, CTS, DCD, GND (RJ45) |
|
|
|
|
|
Supports RS-422, 2-wire RS-485 (DIP
Switch selectable)
Supports 4-wire RS-422, up to 10 nodes, 1.2 km with RTS, CTS
Supports 2-wire RS-485, up to 32 nodes, 1.2 km
|
|
|
| RS-485 Data
Direction Control |
|
|
|
|
|
|
|
|
|
|
| |
Environmental |
|
|
|
| |
Power |
|
|
|
|
|
|
| Protection against 2 signals shorted together |
|
|
|
|
A52: 170 mA @ 9V
A53: 285 mA @ 9V |
|
|
|
|
| |
Mechanical |
|
|
|
| |
Regulatory Approvals |
|
|
|
| |
Warranty |
|
|
|
| |
|